In the NMC OSCE mid-stream urine analysis station, candidates are expected to demonstrate proficiency in collecting, testing, and explaining urine samples. Here are common mistakes that candidates often make in this station:
1. NMC OSCE MSU Station- Incorrect Collection Process
- Failure to explain the process clearly: Not explaining to the patient how to correctly provide a mid-stream urine sample (i.e., passing the first part of urine before collecting the middle stream).
- Not using sterile equipment: Failing to use or ensure the patient uses sterile containers for the sample collection.
2. NMC OSCE MSU Station- Inadequate Infection Control
- Poor hand hygiene: Not washing hands or failing to use alcohol-based hand rub before and after the procedure.
- Not wearing gloves appropriately: Either failing to put on gloves when handling the urine sample or not removing gloves after handling it.
- Cross-contamination: Touching non-sterile surfaces or objects with gloved hands, risking contamination.
3. NMC OSCE MSU Station- Inadequate Time Management
- Spending too much time explaining or preparing, which may leave insufficient time for the actual collection and documentation.
4. NMC OSCE MSU Station- Errors in Urinalysis
- Incorrect use of dipsticks: Using the urine dipstick incorrectly, such as not fully immersing it in the sample or not following the required time frame for reading the results.
- Reading the results too soon or too late: Misinterpreting dipstick results by either reading them too early or too late, which can result in incorrect findings.
- Not identifying abnormal results: Failing to recognize abnormal findings, such as elevated glucose, protein, or leukocytes, and not documenting or escalating these appropriately.
5. NMC OSCE MSU Station- Inadequate Communication
- Miscommunication of results: Either not explaining the results clearly or failing to reassure the patient when results are normal.
- Poor documentation: Incomplete or inaccurate documentation of findings, missing important details.
6. Failure to Dispose of Waste Properly
- Incorrect waste disposal: Not disposing of used materials, such as the dipstick or urine container, in the appropriate clinical waste bin.
Avoiding these mistakes requires careful attention to infection control practices, clear communication, and adherence to the procedures for testing and interpreting urine samples. Practicing these points keeping in mind will help you improve your performance at the Mid-stream Urine analysis station.
NMC OSCE For nurses Everything You Need to Know in 2024 👉 Click Here
For Any NMC OSCE Related Queries and Training Chat with Us!